| ASCII - Command | SLACCMAX | |||
| Syntax Transmit | SLACCMAX [Data] | |||
| Syntax Receive | SLACCMAX <Data> | Available in | ||
| Type | Variable rw | MMI | No | |
| ASCII Format | Integer32 | CANBus Object Number | - | |
| DIM | - | PROFIBUS PNU | - | |
| Range | 1 .. 268435455 | DPR | No | |
| Default | 10 | |||
| Opmode | All | Data Type Bus/DPR | Integer32 | |
| Drive State | - | Weighting | ||
| Start Firmware | - | |||
| Configuration | No | Last Change of this Object | 2.11 | |
| Function Group | sensorless | EEPROM | Yes | |
| Short Description | slopes in sensorless mode | |||
Description
| The parameter SLACCMAX desribe the ramp in sensorless mode. At the beginning, try at most SLACCMAX = ACC = DEC. If this value shows troubles at transition point, make the slopes slower, specially the value for SLACCMAX |