| ASCII - Command | AN2TRIG | |||
| Syntax Transmit | AN2TRIG [Data] | |||
| Syntax Receive | AN2TRIG <Data> | Available in | ||
| Type | Variable rw | MMI | No | |
| ASCII Format | Integer32 | CANBus Object Number | 36A2 (hex) | |
| DIM | - | PROFIBUS PNU | 2018 (dec) IND = 1 (dec) | |
| Range | Long Int | DPR | 418 (dec) | |
| Default | 100 | |||
| Opmode | All | Data Type Bus/DPR | Integer32 | |
| Drive State | - | Weighting | ||
| Start Firmware | 4.93 | |||
| Configuration | No | Last Change of this Object | 1.7 | |
| Function Group | Analog I/O | EEPROM | Yes | |
| Short Description | Scaling of the analog output 2 | |||
Description
| AN2TRIG scales the analog output. The scaling is done in %. Example: ANOUT2 = 1 Actual velocity AN2TRIG = 100 10V at the output at actual velocity=VLIM AN2TRIG = 50 5V at the output at actual velocity=VLIM AN2TRIG = 200 10V at the output at actual velocity=VLIM/2 If ANOUT2=8 is selected (constant voltage), AN2TRIG gives the voltage in mV. |