ASCII - Command ANZERO2    
Syntax Transmit ANZERO2    
Syntax Receive ANZERO2   Available in  
Type Command   MMI Yes
ASCII Format -   CANBus Object Number 3510 (hex)
DIM -   PROFIBUS PNU 1616 (dec) IND = 1 (dec)
Range -   DPR 16 (dec)
Default -    
Opmode All   Data Type Bus/DPR -
Drive State -   Weighting  
Start Firmware 1.20    
Configuration No   Last Change of this Object 1.3
Function Group Analog I/O   EEPROM -
Short Description Zero Analog Input SW2

Description

This command can be used to start the automatic offset correction for the analog input 2. The command at analog input 2 should be short-circuited before using this command. After the command has been carried out, the offset value that was determined is available in the ANOFF2 parameter. To save this value permanently in the EEPROM, you should use the SAVE (save to EEPROM) command.