ASCII - Command DECDIS    
Syntax Transmit DECDIS [Data]    
Syntax Receive DECDIS <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Integer16   CANBus Object Number 3523 (hex)
DIM >> ACCUNIT   PROFIBUS PNU 1635 (dec) IND = 1 (dec)
Range 1 .. 32767, VLIM * 4480 (5.41)   DPR 35 (dec)
Default 10    
Opmode All   Data Type Bus/DPR Integer16
Drive State -   Weighting  
Start Firmware 1.20    
Configuration No   Last Change of this Object 1.3
Function Group Velocity Controller   EEPROM Yes
Short Description Deceleration used on Disable Output Stage

Description

When the output stage is disabled (removal of the hardware or software enable), the internal velocity command is set to 0, using the preset DECDIS ramp. The output stage is only disabled when the actual velocity has fallen below the standstill threshold (VEL0).
The DECDIS ramp only has an effect for motors with a configured brake (MBRAKE=1) or with the selection STOPMODE=1.
With STOPMODE=0 the output stage is immediately disabled, and the drive coasts down.