ASCII Objekt-Reference 

 

Home 

Screen page "Drive status" 


Run time 

ASCII: TRUN 

Default: - 

valid for all OPMODES 

Display of the operational time of the servo amplifier, saved at 8 minute intervals. If the 24V-supply is switched off, maximum 8 minutes of operation are unregistered.
 


Last 10 faults 

ASCII: FLTHIST 

Default: - 

valid for all OPMODES 

The last 10 faults that occurred are displayed, together with the time of their occurrence, referred to the operating hours.
 


Rate of occurrence 

ASCII: FLTCNT 

Default: - 

valid for all OPMODES 

Display of the frequency of all faults that caused the servo amplifier to switch off.
 


Actual errors 

ASCII: ERRCODE 

Default: - 

valid for all OPMODES 

Display of the errors presently being reported by the servo amplifier (corresponds to the error messages Fxx in the LED-display on the front panel of the amplifier)
 


Actual warnings 

ASCII: STATCODE 

Default: - 

valid for all OPMODES 

Display of the warnings presently being reported by the servo amplifier (corresponds to the
warnings nxx in the LED-display on the front panel of the amplifier)
 


Reset 

ASCII: CLRFAULT 

Default: - 

valid for all OPMODES 

Software-reset of the servo amplifier. The servo amplifier must be disabled.
Present errors are deleted, the firmware is re-initialized, and communication is re-established.
If only errors marked with an asterisk in the error listing are present, then the errors are canceled, but no reset of the amplifier takes place.