| ASCII - Command | MSPEED | |||
| Syntax Transmit | MSPEED [Data] | |||
| Syntax Receive | MSPEED <Data> | Available in | ||
| Type | Variable rw | MMI | Yes | |
| ASCII Format | Float | CANBus Object Number | 35A3 (hex) | |
| DIM | rpm | PROFIBUS PNU | 1763 (dec) IND = 1 (dec) | |
| Range | 0.0 .. 12000.0 | DPR | 163 (dec) | |
| Default | 3000 | |||
| Opmode | All | Data Type Bus/DPR | Integer32 | |
| Drive State | - | Weighting | 1000 | |
| Start Firmware | 1.0 | |||
| Configuration | No | Last Change of this Object | 2.10 | |
| Function Group | motor | EEPROM | Yes | |
| Short Description | Maximum Rated Motor Velocity | |||
Description
| The MSPEED sets the upper limit for the following amplifier parameters: VLIM, VLIMN, 5/6 * VOSPD. In all sensorless modes (FBTYPE = 10.11), the output frequency is limited to 599 Hz. This yields the following limits of maximum speed (in RPM): MSPEED (max) = 599Hz * 60 / (MPOLES/2) If your application requires a higher output frequency, please contact our support. Details are shown at parameter VUNIT . |