ASCII - Command MSPEED    
Syntax Transmit MSPEED [Data]    
Syntax Receive MSPEED <Data>   Available in  
Type Variable rw   MMI Yes
ASCII Format Float   CANBus Object Number 35A3 (hex)
DIM rpm   PROFIBUS PNU 1763 (dec) IND = 1 (dec)
Range 0.0 .. 12000.0   DPR 163 (dec)
Default 3000    
Opmode All   Data Type Bus/DPR Integer32
Drive State -   Weighting 1000
Start Firmware 1.20    
Configuration No   Last Change of this Object 1.3
Function Group Motor   EEPROM Yes
Short Description Maximum Rated Motor Velocity

Description

The MSPEED setting fixes the upper limit for the following amplifier parameters: VLIM, VLIMN,
5/6 * VOSPD.

From firmware 4.0 the limit can be set by different units. Details are shown at parameter VUNIT .