You are here: Setup Wizard > Motor > Field Weakening

Field Weakening

Parameter settings for a speed-dependent phase lead (field weakening for permanent magnet servomotors). Please also refer to the KDN page Phase Lead for more information.

 

Screen text

ASCII Parameter

upper diagram for AKM, VLM, Cartridge motors with overhead magnets

Degree:

MVANGLF

lower diagram for all Goldline motors with burried magnets

Degree:

MVANGLP

speed threshold

MVANGLB

V_max

VLIM

Activate SR600 compatibility mode

MVANGLMODE

For motors made by other manufacturers, please request this information from the manufacturer concerned.