ASCII - Command | PARDUMP | |||
Syntax Transmit | PARDUMP | |||
Syntax Receive | PARDUMP <Data> | Available in | ||
Type | Multi-line Return Command | MMI | No | |
ASCII Format | String | CANBus Object Number | - | |
DIM | PROFIBUS PNU | - | ||
Range | DPR | No | ||
Default | - | |||
Opmode | All | Data Type Bus/DPR | String | |
Drive State | - | Weighting | ||
Start Firmware | 2.13 | |||
Configuration | No | Last Change of this Object | 1.8 | |
Function Group | drive configuration | EEPROM | No | |
Short Description | List of switchable parameter sets |
Description
The ASCII parameter PARDUMP lists all drive parameters that are included in the switchable parameter set. ACC,DEC,GP,GPFFT,GPFFV,GV,GVFR,GVTN,KC,KTN,MICONT,MIPEAK,MJ,MKT,ML MLGC,MLGD,MLGP,MLGQ,MPOLES,MRS,MTIME,VLO The output looks like this: GP 0.1 (GP_X 0.2) GV 1.5 (GV_X 3) Data Set 1 activ The first parameter in every line ist the ascii parameter from the main parameter set. The parameter in brackets is the ascii parameter from the second (shadow) parameter set. The last line indicates the currently active parameter set. |